Excess Molar Volumes of the Heptane–1-Chloropentane System at High Pressures and Elevated Temperatures

Linek, J. and Morávková, L. Excess Molar Volumes of the Heptane–1-Chloropentane System at High Pressures and Elevated Temperatures Chemical Papers, Vol.55, No. 6, 2001, 382-385

Document type: Článok z časopisu / Journal Article
Collection: Chemical papers  

Author(s) Linek, J.
Morávková, L.
Title Excess Molar Volumes of the Heptane–1-Chloropentane System at High Pressures and Elevated Temperatures
Journal name Chemical Papers
Publication date 2001
Year available 2001
Volume number 55
Issue number 6
ISSN 0366-6352
Start page 382
End page 385
Place of publication Poland
Publisher Versita
Collection year 2001
Language english
Subject 290000 Engineering and Technology
290600 Chemical Engineering
290602 Process Control and Simulation
Abstract/Summary The apparatus for p-V -T measurements of liquids and liquid mixtures was designed and tested. It works in the temperature range of 283 to 333 K and pressure range of 0.1 to 40 MPa with an overall accuracy of density measurement 1 x 10−4 g cm−3. Its main part is a high-pressure vibrating tube densimeter working in a static mode. The apparatus was used for measuring the p-V -T relations of the heptane—1-chloropentane system. Excess molar volumes were calculated from the data and tted to the Redlich—Kister equation.
 
 