Residence time distribution study for the catalytic packing MULTIPAK®
Górak, A., Jaroszyński, M. and Kołodziej, A. Residence time distribution study for the catalytic packing MULTIPAK® Chemical Papers, Vol.60, No. 6, 2006, 404-409
|
|
Document type:
|
Článok z časopisu / Journal Article |
Collection:
|
Chemical papers
|
|
Author(s) |
Górak, A. Jaroszyński, M. Kołodziej, A.
|
Title |
Residence time distribution study for the catalytic packing MULTIPAK®
|
Journal name |
Chemical Papers
|
Publication date |
2006
|
Year available |
2006
|
Volume number |
60
|
Issue number |
6
|
ISSN |
0366-6352
|
Start page |
404
|
End page |
409
|
Place of publication |
Poland
|
Publisher |
Versita
|
Collection year |
2006
|
Language |
english
|
Subject |
290000 Engineering and Technology 290600 Chemical Engineering
|
Abstract/Summary |
Residence time distribution (RTD) experiments were carried out using the catalytic packing MULTIPAK® in a 250 mm inner diameter column. The axial dispersion coefficients and dynamic liquid hold-up were derived from the RTD curves. Both hold-up and axial Péclet number were correlated in terms of gas and liquid Reynolds numbers. Free-draining experiments were performed to determine the dynamic and static liquid hold-ups. The measured axial dispersion coefficients were higher than those presented in other studies. The dynamic hold-up derived from RTD agreed with total hold-up from free-draining experiments. The static hold-up was found very high, even higher than the dynamic one, due to the liquid accumulated inside the catalyst bed. Possibly, the liquid considered “static” from the viewpoint of the free-draining experiments becomes “dynamic” during the normal column operation.
|
|
|